Alternator Features:
1)Advanced automatic voltage regulator control for trouble-free operation under the most demanding condition
2)Easy paralleling with mains or other generators. Standard 2/3 pitch windings avoid excessive neutral currents.
3) Dynamically balanced rotor, with sealed-for-life ball bearings and single or two-bearing construction.
4)Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts.
5)Wide range of Flange adaptor and single bearing coupling disc.
All of the alternator rotors should pass balance test, whose vibrations are lower than the minimum of BS6861 P.1, G 2.5 two bearing alternator has a half-key testing balance
Terminal and terminal box
The three-field alternator had 12 leads brought out to the terminals in the terminal box. The terminals are put on the non-drive end. The box is equipped with removable panels.
Winding and electric features
2/3 pith winding design can effectively eliminate the third harmonic wave(3th.9th,15th) of the voltage, which is the best design of UPS for a nonlinear load. Connected with the network in parallel, the structure can restrain excessive currents in the midline. This and the 2/3 pitch help to check the wave distortion and output voltage.
1)Advanced automatic voltage regulator control for trouble-free operation under the most demanding condition
2)Easy paralleling with mains or other generators. Standard 2/3 pitch windings avoid excessive neutral currents.
3) Dynamically balanced rotor, with sealed-for-life ball bearings and single or two-bearing construction.
4)Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts.
5)Wide range of Flange adaptor and single bearing coupling disc.
All of the alternator rotors should pass balance test, whose vibrations are lower than the minimum of BS6861 P.1, G 2.5 two bearing alternator has a half-key testing balance
Terminal and terminal box
The three-field alternator had 12 leads brought out to the terminals in the terminal box. The terminals are put on the non-drive end. The box is equipped with removable panels.
Winding and electric features
2/3 pith winding design can effectively eliminate the third harmonic wave(3th.9th,15th) of the voltage, which is the best design of UPS for a nonlinear load. Connected with the network in parallel, the structure can restrain excessive currents in the midline. This and the 2/3 pitch help to check the wave distortion and output voltage.